> For the complete documentation index, see [llms.txt](https://docs.vergeos-demo.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.vergeos-demo.com/learn-the-platform/module-9-monitoring-and-troubleshooting/05-diagnostics-toolkit.md).

# Diagnostics Toolkit

## Four Diagnostic Toolkits in One Platform

VergeOS embeds diagnostic tools directly into every major subsystem. Rather than SSH-ing into individual nodes or installing third-party utilities, administrators run diagnostics from the **VergeOS UI** — each scoped to the component being investigated.

```mermaid
graph LR
    subgraph "VergeOS Diagnostics"
        A["Network<br/>Diagnostics"] --> E["Unified UI"]
        B["Node<br/>Diagnostics"] --> E
        C["vSAN<br/>Diagnostics"] --> E
        D["NAS<br/>Diagnostics"] --> E
    end
    E --> F["Results &<br/>CLI Export"]

    style A fill:#4a90d9,color:#fff
    style B fill:#e67e22,color:#fff
    style C fill:#27ae60,color:#fff
    style D fill:#8e44ad,color:#fff
    style E fill:#2c3e50,color:#fff
    style F fill:#34495e,color:#fff
```

Every diagnostic interface follows the same pattern:

1. Navigate to the component (network, node, NAS, or vSAN)
2. Click **Diagnostics** in the left menu
3. Select a command from the **Query** dropdown
4. Configure parameters on the right
5. Click **Send →** to execute

{% hint style="success" %}
**Show Command Toggle**

Enable **"Show Command"** on any diagnostic to see the exact CLI syntax being executed. This is invaluable for scripting, automation, or reproducing commands over SSH.
{% endhint %}

***

## Network Diagnostics

**Access:** Networks → \[Select Network] → Diagnostics

Network diagnostics run **per-network** — you select the specific network you want to troubleshoot, and all commands execute within that network's context. This is critical because VergeOS networks are isolated by design.

### Connectivity & Discovery

| Command                 | CLI Equivalent                    | Purpose                                            |
| ----------------------- | --------------------------------- | -------------------------------------------------- |
| **Ping**                | `ping -c [COUNT] [DEST]`          | Basic ICMP connectivity test                       |
| **Trace Route**         | `traceroute` / `mtr`              | Map the network path to a destination              |
| **ARP Scan**            | `nmap -sn [RANGE]`                | Discover active devices on the network             |
| **ARP Table**           | `arp -a`                          | View current IP-to-MAC mappings                    |
| **TCP Connection Test** | `telnet` / `nc -zv [HOST] [PORT]` | Verify a specific TCP port is reachable            |
| **What's My IP**        | `curl ifconfig.me`                | Check the network's external IP (NAT verification) |

### DNS & Name Resolution

| Command        | CLI Equivalent                   | Purpose                            |
| -------------- | -------------------------------- | ---------------------------------- |
| **DNS Lookup** | `nslookup` / `dig [HOST] [TYPE]` | Query A, AAAA, MX, NS, PTR records |

### Firewall & Security

| Command                        | CLI Equivalent            | Purpose                               |
| ------------------------------ | ------------------------- | ------------------------------------- |
| **Show Firewall Rules**        | `nft list ruleset`        | Display the full nftables ruleset     |
| **Trace/Debug Firewall Rules** | `nft add rule ... log`    | Enable per-rule logging for debugging |
| **NMAP**                       | `nmap [OPTIONS] [TARGET]` | Port scanning and service discovery   |

### Traffic Analysis

| Command               | CLI Equivalent                | Purpose                           |
| --------------------- | ----------------------------- | --------------------------------- |
| **TCP Dump**          | `tcpdump -i [IFACE] [FILTER]` | Packet capture with BPF filtering |
| **Top Network Usage** | `iftop` / `nethogs`           | Real-time bandwidth consumers     |
| **Top CPU Usage**     | `top -o %CPU`                 | Processes consuming the most CPU  |

### Service-Specific

| Command                | CLI Equivalent            | Purpose                                         |
| ---------------------- | ------------------------- | ----------------------------------------------- |
| **DHCP Release/Renew** | `dhclient -r && dhclient` | Force DHCP lease refresh (DHCP client networks) |
| **IPsec**              | `ipsec [COMMAND]`         | Monitor and control IPsec VPN tunnels           |
| **FRRouting BGP/OSPF** | `vtysh -c "show ip bgp"`  | Dynamic routing protocol status                 |
| **Logs**               | `journalctl -u [SERVICE]` | Network container system logs                   |

{% hint style="info" %}
**Tenant Access**

Tenants have access to their own network diagnostics for tenant-specific networks. These tools operate within the tenant's network scope — they cannot see parent-level networks.
{% endhint %}

***

## Node Diagnostics

**Access:** Infrastructure → Nodes → \[Select Node] → Diagnostics

Node diagnostics provide **hardware-level** visibility into individual physical servers. These tools interact directly with the server's BMC, drives, and physical network interfaces.

### IPMI / BMC Tools

These commands use `ipmitool` to communicate with the server's Baseboard Management Controller — the out-of-band management interface (iDRAC on Dell, iLO on HPE, etc.).

| Command                         | CLI Equivalent            | Purpose                               |
| ------------------------------- | ------------------------- | ------------------------------------- |
| **IPMI BMC Info**               | `ipmitool bmc info`       | BMC firmware and configuration        |
| **IPMI Chassis Status**         | `ipmitool chassis status` | Power state, intrusion detection      |
| **IPMI FRU Info**               | `ipmitool fru print`      | Field Replaceable Unit identification |
| **IPMI LAN Info**               | `ipmitool lan print`      | BMC network configuration             |
| **IPMI MC Reset**               | `ipmitool mc reset cold`  | Reset a non-responsive BMC            |
| **IPMI Sensors**                | `ipmitool sensor list`    | Temperature, voltage, fan readings    |
| **IPMI Sensor Data Repository** | `ipmitool sdr list`       | Full sensor data repository           |
| **IPMI System Event Logs**      | `ipmitool sel list`       | Hardware event history (SEL)          |

{% hint style="warning" %}
**IPMI MC Reset**

Resetting the BMC temporarily disrupts out-of-band management. The host OS continues running — this only affects the management controller.
{% endhint %}

### Drive & Storage Health

| Command                        | CLI Equivalent                                        | Purpose                                                                |
| ------------------------------ | ----------------------------------------------------- | ---------------------------------------------------------------------- |
| **S.M.A.R.T. Information**     | `smartctl -a [DRIVE]`                                 | Drive health attributes, wear, temperature                             |
| **S.M.A.R.T. Diagnostic Test** | `smartctl -t [TYPE] [DRIVE]`                          | Run short, long, or conveyance tests                                   |
| **Show Block Devices**         | `lsblk` / `fdisk -l`                                  | List all block devices on the node                                     |
| **LED Control (Drive)**        | `ledctl locate=[DRIVE]` / `ledctl locate_off=[DRIVE]` | Activate/deactivate the drive's locate LED for physical identification |
| **RAS Query**                  | `ras-mc-ctl --summary`                                | Memory ECC error reporting                                             |

### Network & Fabric

| Command                  | CLI Equivalent                 | Purpose                                |
| ------------------------ | ------------------------------ | -------------------------------------- |
| **Ethernet Tool**        | `ethtool [IFACE]`              | Link speed, duplex, driver info        |
| **Fabric Configuration** | `verge fabric show`            | Core fabric status for this node       |
| **Network Bonding**      | `cat /proc/net/bonding/[BOND]` | Bond interface health and active slave |
| **Bridge Addresses**     | `brctl showmacs [BRIDGE]`      | Virtual switch MAC address table       |
| **ARP Scan / ARP Table** | `nmap -sn` / `arp -a`          | Node-level network discovery           |
| **Ping / Trace Route**   | `ping` / `traceroute`          | Basic connectivity from node context   |

### System

| Command                      | CLI Equivalent                              | Purpose                                            |
| ---------------------------- | ------------------------------------------- | -------------------------------------------------- |
| **DMI Table**                | `dmidecode`                                 | Full hardware inventory (CPU, RAM, serial numbers) |
| **Logs**                     | `journalctl -n 100` / `dmesg`               | System and kernel logs                             |
| **OpenSSL Speed**            | `openssl speed`                             | CPU crypto performance benchmark                   |
| **Clear Persistent Storage** | `sync && echo 3 > /proc/sys/vm/drop_caches` | Clear filesystem caches (support use only)         |

{% hint style="info" %}
**Coming from VMware or Nutanix?**
{% endhint %}

| Platform | Where deep hardware inspection happens                                                                                                                                   |
| -------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
| VMware   | SSH/DCUI to the ESXi host for `esxcli`/`vsish`; vCenter exposes some SMART/sensors but deep work leaves the vSphere UI                                                   |
| Nutanix  | Prism Element Hardware page + `ncli` from the CVM; IPMI/BMC accessed separately for drive LED and detailed sensors                                                       |
| VergeOS  | Single node diagnostics panel: IPMI, SMART, drive LED control, fabric health, with no SSH or separate BMC credentials. "Show Command" exports the underlying CLI syntax. |

***

## vSAN Diagnostics

**Access:** System → vSAN Diagnostics

vSAN diagnostics operate at the **system level** using `vcmd` — the VergeOS vSAN command-line interface. These commands provide deep visibility into the distributed storage engine.

{% hint style="warning" %}
**Root / Parent Level Only**

vSAN diagnostics are only available at the root/parent level. **Tenants do not have access** to vSAN diagnostic tools — they interact with storage through their allocated virtual disks.
{% endhint %}

### Key vcmd Commands

| Command                    | CLI Equivalent                 | Purpose                                       |
| -------------------------- | ------------------------------ | --------------------------------------------- |
| **Get Tier Status**        | `vcmd tier status`             | Health, redundancy, and capacity per tier     |
| **Get Cluster Rates**      | `vcmd cluster rates`           | Read/write throughput across the cluster      |
| **Get Cluster Usage**      | `vcmd cluster usage`           | Overall storage utilization statistics        |
| **Get Device List**        | `vcmd devices list`            | All storage devices in the vSAN pool          |
| **Get Device Status**      | `vcmd device status [ID]`      | Individual device health and error counts     |
| **Get Device Usage**       | `vcmd device usage [ID]`       | Per-device capacity and I/O metrics           |
| **Get Repair Status**      | `vcmd repair status`           | Active rebuild/repair progress                |
| **Get Journal Status**     | `vcmd journal status`          | Write-ahead journal health                    |
| **Get Integ Check Status** | `vcmd integcheck status`       | Data integrity verification progress          |
| **Get Cache Info**         | `vcmd cache info`              | Cache hit/miss ratios and memory usage        |
| **Get File Status**        | `vcmd file status [FILE_PATH]` | Replication and integrity for a specific file |
| **Get Top Usage Rates**    | `vcmd usage top-rates`         | Identify top storage consumers                |
| **Get Running Conf**       | `vcmd config show`             | Current vSAN configuration parameters         |
| **Get Sync List**          | `vcmd sync list`               | Active synchronization operations             |
| **Get Node List**          | `vcmd nodes list`              | All nodes participating in the vSAN           |
| **Integ Check**            | `vcmd integcheck start`        | Initiate a full integrity check               |
| **Summarize Disk Usage**   | `vcmd usage summarize`         | Cluster-wide disk usage summary               |

### vSAN Health Check Workflow

A structured approach to investigating storage issues:

```mermaid
flowchart TD
    A["Check Tier Status"] --> B{All tiers<br/>working = true?}
    B -->|Yes| C["Check Cluster Rates"]
    B -->|No| D["Check Repair Status"]
    D --> E["Check Device Status<br/>for failed drives"]
    C --> F{Performance<br/>acceptable?}
    F -->|Yes| G["System Healthy"]
    F -->|No| H["Check Cache Info"]
    H --> I["Check Top Usage Rates"]
    I --> J["Identify bottleneck"]
    E --> K["Check SMART data<br/>via Node Diagnostics"]

    style A fill:#27ae60,color:#fff
    style G fill:#27ae60,color:#fff
    style D fill:#e74c3c,color:#fff
    style E fill:#e74c3c,color:#fff
```

### Key Indicators to Monitor

* **`working = false`** on any tier → Critical — tier is not operational
* **`redundant = false`** → Degraded state, no fault tolerance
* **`bad_drives > 0`** → Drive failure detected, auto-repair in progress
* **Repair status all zeros** → No active repairs (healthy state)
* **Write throttle active** → Storage capacity approaching limits (>91% triggers throttling)

### Storage Space Throttling Thresholds

| Utilization | Behavior                                         |
| ----------- | ------------------------------------------------ |
| **< 91%**   | Normal operation, no throttling                  |
| **91–95%**  | Low-space throttling begins (10ms latency added) |
| **96%+**    | Critical throttling (50ms latency added)         |
| **> 96%**   | Severe performance degradation                   |

***

## NAS Diagnostics

**Access:** NAS → \[Select NAS Service] → Diagnostics

NAS diagnostics are **per-NAS-service** — each NAS instance has its own diagnostic interface. These tools focus on file-sharing protocols (SMB/CIFS, NFS) and authentication.

### CIFS/SMB Diagnostics

| Command   | CLI Equivalent           | Purpose                                 |
| --------- | ------------------------ | --------------------------------------- |
| **Samba** | `smbstatus`              | Active SMB connections and locked files |
|           | `testparm`               | Validate Samba configuration syntax     |
|           | `smbclient -L localhost` | List available SMB shares               |

### NFS Diagnostics

| Command | CLI Equivalent | Purpose                                 |
| ------- | -------------- | --------------------------------------- |
| **NFS** | `exportfs -v`  | Current NFS export configuration        |
|         | `rpcinfo -p`   | RPC service registration status         |
|         | `showmount -e` | Exported filesystems visible to clients |

### Active Directory / Winbind

| Command     | CLI Equivalent | Purpose                        |
| ----------- | -------------- | ------------------------------ |
| **Winbind** | `wbinfo -t`    | Test domain trust relationship |
|             | `wbinfo -u`    | List domain users              |
|             | `wbinfo -g`    | List domain groups             |

### Standard Network Tools

NAS diagnostics also include the standard connectivity tools: **Ping**, **Trace Route**, **ARP Scan/Table**, **TCP Dump**, **TCP Connection Test**, **DNS Lookup**, **NTP Query**, **Top CPU Usage**, **Top Network Usage**, and **Logs**.

### User & Group Diagnostics

| Command       | CLI Equivalent                        | Purpose                              |
| ------------- | ------------------------------------- | ------------------------------------ |
| **Users**     | `getent passwd` / `who`               | System user accounts                 |
| **Groups**    | `getent group`                        | System groups and membership         |
| **Date/Time** | `date` / `timedatectl`                | Time sync (critical for Kerberos/AD) |
| **Services**  | `systemctl list-units --type=service` | All running services                 |

***

## Best Practice Troubleshooting Workflow

When investigating an issue, follow a structured escalation path from component-specific diagnostics to system-wide analysis:

```mermaid
flowchart TD
    A["1. Define Scope"] --> B["What component is affected?<br/>Network? Storage? Hardware? NAS?"]
    B --> C["2. Component Diagnostics"]
    C --> D["Use the matching toolkit:<br/>Network → Network Diags<br/>Storage → vSAN Diags<br/>Hardware → Node Diags<br/>File Shares → NAS Diags"]
    D --> E{"Issue<br/>resolved?"}
    E -->|Yes| F["Document findings"]
    E -->|No| G["3. System Diagnostics"]
    G --> H["System → System Diagnostics<br/>Generates full diagnostic bundle"]
    H --> I{"Issue<br/>resolved?"}
    I -->|Yes| F
    I -->|No| J["4. Escalate to Support"]
    J --> K["Attach diagnostic bundle<br/>Include timeline & symptoms"]

    style A fill:#3498db,color:#fff
    style C fill:#2ecc71,color:#fff
    style G fill:#f39c12,color:#fff
    style J fill:#e74c3c,color:#fff
```

### Workflow Guidelines

1. **Start simple** — Ping before packet capture. Check tier status before integrity checks.
2. **Scope correctly** — Select the right network, node, or NAS service before running diagnostics. Running commands in the wrong context produces misleading results.
3. **Document as you go** — Use "Show Command" to capture exact commands. Copy output before moving to the next test.
4. **Consider performance impact** — TCP Dump, NMAP scans, and integrity checks can affect production performance. Schedule intensive diagnostics during maintenance windows.
5. **Check logs last** — Logs provide context but can be overwhelming. Use targeted diagnostics first, then correlate with log entries.

### System Diagnostics Bundle

For issues that span multiple components or require support escalation, VergeOS can generate a **full diagnostic bundle**:

* **Access:** System → System Diagnostics
* **Output:** `[SYSTEMNAME]_diags_[YYYYMMDD]_[HHMMSS].tar.gz`
* **Contents:** vSAN status files, SMART reports, network configuration, IPMI data, system logs, and kernel logs — organized per-node
* **Bundle storage:** Saved as a `files` record in vSAN; the bundle persists until you delete it

{% hint style="info" %}
**UI Log Retention vs. Bundle Retention**

The diagnostic bundle itself has no automatic expiration. Separately, VergeOS retains live UI **system logs for 45 days** before automatic deletion — configure remote syslog forwarding if you need longer log history.
{% endhint %}

{% hint style="success" %}
**Before Escalating**

Always generate a fresh System Diagnostics bundle before contacting support. This provides a complete point-in-time snapshot that support engineers can analyze without needing live system access.
{% endhint %}

***

## Quick Reference: Which Toolkit to Use

### Network Diagnostics

**Use when:** VM can't reach the internet, DNS not resolving, firewall blocking traffic, DHCP not assigning IPs, VPN tunnel down

**Access:** Networks → \[Network] → Diagnostics

### Node Diagnostics

**Use when:** Hardware alerts, drive failures, temperature warnings, NIC link issues, IPMI unresponsive, fabric connectivity problems

**Access:** Infrastructure → Nodes → \[Node] → Diagnostics

### vSAN Diagnostics

**Use when:** Storage performance degraded, tier unhealthy, capacity warnings, repair stuck, data integrity concerns

**Access:** System → vSAN Diagnostics

### NAS Diagnostics

**Use when:** SMB shares inaccessible, NFS mount failures, AD authentication broken, file permission denied, slow CIFS performance

**Access:** NAS → \[NAS Service] → Diagnostics


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter:

```
GET https://docs.vergeos-demo.com/learn-the-platform/module-9-monitoring-and-troubleshooting/05-diagnostics-toolkit.md?ask=<question>
```

The question should be specific, self-contained, and written in natural language.
The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.